· Help: Templates Add & Edit - CU TechnoGym |
|
Control Unit: Group membership enables locking of more than one locker with one ticket (Card, Wristband, etc.). Exactly one locker can be locked with one card in each group. 4 different groups are available or standalone, which means each Control Unit is in its own group.
Payment: Enabled if "On" is selected. Payment for locker usage is achieved by connecting a Coin acceptor to each Control Unit.
Payment - Display: Text displayed after coin is inserted.
Payment - Coin Value: Value of coin accepted by the Coin Acceptor
Payment - Number of Coins per Locking: Number of coins required for successful locking.
Payment - Tenancy: In what time the locker can be locked again by same ticket without additional payment.
Payment - Coin Waiting time: System waits for chosen number of seconds for coin to be inserted.
Payment - Payment Timeout: If coins are inserted in advance, payment is valid for chosen time and during that time Locker must be closed and ticket presented otherwise the payment is invalid.
Automatic Opening: If " - Checked" once the Locker is closed and successfully locked it automatically opens after the entered time (in minutes).
Locking Authorized by Server (ex White List parameter): If " - Checked" the Control Unit asks Metra server via Metra NET Network if particular ticket has permission to lock the Locker.
Alarm: Alarm beep duration.
Remote unlocking: If " - Checked" the Lockers can be opened remotely by pressing the emergency open push button or automatically every single day at set time. See Hardware\Metra Network\Remote Unlocking or Hardware\Metra Network\Templates for additional information.
User Waiting - Time: After the Locker door is closed, system waits for ticket to be presented for chosen number of seconds.
User Waiting - Time increment: If " - Checked" user waiting time increments (slower countdown) after the countdown ended without presenting the ticket to lock the locker. This gives user more time to present the ticket in second attempt.
User Waiting - Audio Signal: Audio signal volume. Can be set to "Off" (silent), Low or High.
Club Code Checking: If " - Checked" Control Unit can check TechnoGym key for correct Club Code. Up to 15 different Club Codes can be stored into the Control Unit.
Club Code Checking - List: Click on button. After you are prompted, insert the TechnoGym key in the TechnoGym desktop reader. Club Code on TechnoGym key will be read and saved. You can also manually type-in the Club Codes.