· Help: Templates Add & Edit - CU Keypad 32

Control Unit Template
Code:
Description:
Hardware:
Payment: Off On Sign Bloc Bloc Time
Payment
Display:
Coin Value:
Number of Coins per Locking:
Additional Payment Limit:
Tenancy:
Coin Waiting time:
Payment Timeout:
Automatic Opening 
Alarm seconds
Alarm Delay seconds
Remote Unlocking
Multi Locking
User Waiting
PIN Length (min): numbers
PIN Request Display: PIN COdE
Time: seconds
Time Increment seconds
Audio Signal: Off On
Special Keys Mode: Off-line On-line

First

Previous

Next

Last

Update

 

Code: Template's ID.

Description: Type-in template's description.

Hardware: Select type of Hardware.

Payment - OFF: Payment is disabled. No tenancy limitations once the Locker is locked.

Payment - On: Payment is enabled. Payment for locker usage is achieved by connecting a Coin acceptor to each Locker Controller (Control Unit).

Payment - SIGn: Payment is disabled. After the Locker is locked and tenancy expired, Locker expired signalization is turned ON (two middle dots on the Display start flashing alternately). When all the Lockers with expired tenancy are unlocked, expired signalization is turned OFF. Also an additional tenancy time sub-parameter is accessible in parameter selecting mode and must be set.

Payment: Off On Sign Bloc Locking Time:

Payment - bLOC: Payment is disabled. After the Locker is locked and tenancy expired, Locker becomes blocked and expired signalization is turned ON (two middle dots on the Display start flashing alternately). Blocked Locker can be unlocked only in Master mode or with Emergency Open and cannot be unlocked by user with corresponding PIN code, RFID media or fingerprint. When all the blocked Lockers are unlocked, expired signalization is turned OFF. Also an additional tenancy time sub-parameter is accessible in parameter selecting mode and must be set.

Payment: Off On Sign Bloc Locking Time:

Payment - Bloc Time: Locker is automatically blocked if it is locked at pre-set time. Block time and allow locking from/to are set on Settings page.

 

After the locker is blocked it can be:

Unblocked - same user key is used as it was used to lock the locker.

Unblocked with PIN code - A new PIN code (locker key) is defined to unlock the locker.

All actions described above can be performed on "View\Blocked Lockers" page.

Payment - Display: Text displayed after coin is inserted.

Payment - Coin Value: Value of coin accepted by the Coin Acceptor

Payment - Number of Coins per Locking: Number of coins required for successful locking. (Requires 4.4.0 Firmware or newer)

Payment - Additional Payment Limit: Number of payments can be set from 1 to 31. If 1 is selected, locker can always be unlocked without additional payment and locker never becomes blocked.

 

Payment - Tenancy: In what time the locker can be locked again by same ticket without additional payment.

Payment - Coin Waiting time: System waits for chosen number of seconds for coin to be inserted.

Payment - Payment Timeout: If coins are inserted in advance, payment is valid for chosen time and during that time Locker must be closed and ticket presented otherwise the payment is invalid.

Automatic Opening: If " - Checked" once the Locker is closed and successfully locked it automatically opens after the entered time (in minutes).

Alarm: Alarm beep duration.

Alarm Delay: After the locker is closed, alarm becomes active after entered time.

Remote unlocking: If " - Checked" the Lockers can be opened remotely by pressing the emergency open push button or automatically every single day at set time. See Hardware\Metra Network\Remote Unlocking or Hardware\Metra Network\Templates for additional information.

Multi locking: If " - Checked" the Multi locking by PIN code is enabled. Type-in the multi locking code.

User Waiting - PIN Length (min): Minimal PIN code length that is accepted as locker key. Example: If set to 4, only 4 digit PIN codes are accepted. If set to 5, only 4 digit PIN codes are accepted and last (fourth) digit entered automatically confirms the entered PIN code and there is no need to press the confirmation key.

User Waiting - PIN Request Display: After the Locker is closed or when unlocking and Pin code is requested, sign "Pin" or sign "Code" can be displayed on the Display.

User Waiting - Time: After the Locker door is closed, system waits for ticket to be presented for chosen number of seconds.

User Waiting - Time increment: If " - Checked" user waiting time increments (slower countdown) after the countdown ended without presenting the ticket to lock the locker. This gives user more time to present the ticket in second attempt.

User Waiting - Audio Signal: Audio signal volume. Can be disabled "Off" (silent) or enabled "On".

Special Keys Mode: If "Off-line" is selected special keys are not downloaded to the device and should be set locally on the device itself, while if "On-line" is selected special keys downloaded to the device from the Metra Server software.

Navigation buttons

Update button

 