Code: Template's ID.
Description: Type-in template's description.
Hardware: Select type of Hardware.
Payment - OFF: Payment
is disabled. No tenancy limitations once the Locker is locked.
Payment - On: Payment is enabled. Payment for locker usage is achieved by connecting a Coin acceptor to each Locker Controller (Control Unit).
Payment - Display: Text displayed after coin is inserted.
Payment - Coin Value: Value of coin accepted by the Coin Acceptor
Payment - Number of Coins per Locking: Number of coins required for successful locking. (Requires 4.4.0 Firmware or newer)
Payment - Additional Payment Limit: Number of payments can be set from 1 to 31. If 1 is selected, locker can always be unlocked without additional payment and locker never becomes blocked.
Payment - Tenancy: In what time the locker can be locked again by same ticket without additional payment.
Payment - Coin Waiting time: System waits for chosen number of seconds for coin to be inserted.
Payment - Payment Timeout: If coins are inserted in advance, payment is valid for chosen time and during that time Locker must be closed and ticket presented otherwise the payment is invalid.
Alarm: Alarm beep duration.
Alarm Delay: After the locker is closed, alarm becomes active after entered time.
Remote unlocking: If " - Checked" the Lockers can be opened remotely by pressing the emergency open push button or automatically every single day at set time. See Hardware\Metra Network\Remote Unlocking or Hardware\Metra Network\Templates for additional information.
User Waiting - PIN Length (min): Minimal PIN code length that is accepted as locker key. Example: If set to 4, only 4 digit PIN codes are accepted. If set to 5, only 4 digit PIN codes are accepted and last (fourth) digit entered automatically confirms the entered PIN code and there is no need to press the confirmation key.
User Waiting - PIN Request Display: After the Locker is closed or when unlocking and Pin code is requested, sign "Pin" or sign "Code" can be displayed on the Display.
User Waiting - Time: After the Locker door is closed, system waits for ticket to be presented for chosen number of seconds.
User Waiting - Time increment: If " - Checked" user waiting time increments (slower countdown) after the countdown ended without presenting the ticket to lock the locker. This gives user more time to present the ticket in second attempt.
User Waiting - Audio Signal: Audio signal volume. Can be disabled "Off" (silent) or enabled "On".
Special Keys Mode: If "Off-line" is selected special keys are downloaded to the device and if "On-line" is selected special keys are checked in real time on Metra server.