· Help: Templates Add & Edit - CU Assign RFID

Control Unit Template
Code:
Description:
Hardware:
Control Unit:
Occupied Locker Signalisation: Off On
Locking Authorized by Server
Alarm seconds
Alarm Delay seconds
Remote Unlocking
Locker Release Confirmation

First

Previous

Next

Last

Update

 

Code: Template's ID.

Description: Type-in template's description.

Hardware: Select type of Hardware.

Control Unit: Group membership enables locking of more than one locker with one ticket (Card, Wristband, etc.). Exactly one locker can be locked with one card in each group. 4 different groups are available or standalone, which means each Control Unit is in its own group.

Occupied Locker Signalisation: This feature can be viewed as information for user which locker was locked by her/his RFID media and where to go to open it. If the RFID media is presented and recognized as a locker key on different device the locker number is flashing on the Display and interrupted acoustic signal is activated. Locker remains closed.

Locking Authorized by Server (ex White List parameter): If " - Checked" the Locker Controller (Control Unit) asks Metra server via Metra NET Network if particular ticket has permission to lock the Locker.

Alarm: Alarm beep duration.

Alarm Delay: After the locker is closed, alarm becomes active after entered time.

Remote unlocking: If " - Checked" the Lockers can be opened remotely by pressing the emergency open push button or automatically every single day at set time. See Hardware\Metra Network\Remote Unlocking or Hardware\Metra Network\Templates for additional information.

Locker Release Confirmation: If " - Checked" upon unlocking your locker device asks you if you want to free the locker for a next user or not and keep using it. If left " - Unchecked" locker will automatically be released upon unlocking. See "ELS ASSIGN - User Manual.pdf" for more information.

Navigation buttons

Update button

 

( Back )