Template is used when there are no UI devices connected or when UI devices without a 12 key keypad are connected.
|
Code: Template's ID.
Description: Type-in template's description.
Hardware: Select type of Hardware.
Alarm: Alarm beep duration.
LED Invite: If "Run" is selected Metra logo on the UI devices connected to the controller board will blink with Metra heartbeat. If "ON" is selected logo will remain ON, while if "OFF" is selected, logo will remain OFF.
Card Read Beep: If "ON" is selected, sound signalization is turned ON for all keys, if "Emergency only" is selected, sound is generated only when a Master keys is presented while if "OFF" is selected, device wont generate any sound at all.
Remote unlocking: If "OFF" lockers will not be unlocked if an unlock command is received. With other 3 options you can set either the lockers can be opened remotely by pressing the emergency open push button and/or automatically every single day at set time. See Hardware\Metra Network\Remote Unlocking or Hardware\Metra Network\Templates for additional information.
Push-Pull Mode: if "OFF" is selected device works as a standard ELS NET device. If seconds are selected "pull to open" or "push to open" functionality is enabled which means that if the locker is not opened it will lock back automatically after set time. Push and/or pull to open Metra Electronic Locks are required for this functionality to work properly.
EX: For FW versions releases after beginning of 2017 you should select "EX15", for older versions contact Metra Support for details.
Block RFID media: Select which types of RFID media the device will not read. Useful for dual RFID cards for which you want to read only a specific RFID chip.