· Help: Templates Add & Edit - MEW Locker Controller 8 Combo PPTO

Control Unit Template
Code:
Description:
Hardware:
Alarm seconds
LED Invite: Run ON OFF
Card Read Beep: ON Master only OFF
Remote Unlocking: OFF Emergency only Timetable only Emergency & Timetable
User Waiting
PIN Request Display: PIN COdE
Push-Pull Mode: seconds
EX: EX10 EX15
Block RFID Media ISO 15693
ISO 14443A
RFU
ISO 14443B
RFU
ISO 14443B SRX
ISO 14443B CEPASS
RFU
RFU
RFU
RFU
RFU
RFU
RFU
RFU
RFU

First

Previous

Next

Last

Update

 

Code: Template's ID.

Description: Type-in template's description.

Hardware: Select type of Hardware.

Alarm: Alarm beep duration.

LED Invite: If "Run" is selected Metra logo on the UI devices connected to the controller board will blink with Metra heartbeat. If "ON" is selected logo will remain ON, while if "OFF" is selected, logo will remain OFF.

Card Read Beep: If "ON" is selected, sound signalization is turned ON for all keys, if "Emergency only" is selected, sound is generated only when a Master keys  is presented while if "OFF" is selected, device wont generate any sound at all.

Remote unlocking: If "OFF" lockers will not be unlocked if an unlock command is received. With other 3 options you can set either the lockers can be opened remotely by pressing the emergency open push button and/or automatically every single day at set time. See Hardware\Metra Network\Remote Unlocking or Hardware\Metra Network\Templates for additional information.

User Waiting - PIN Request Display: After the Locker is closed or when unlocking and Pin code is requested, sign "Pin" or sign "Code" can be displayed on the UI device.

Push-Pull Mode: if "OFF" is selected device works as a standard ELS NET device. If seconds are selected "pull to open" or "push to open" functionality is enabled which means that if the locker is not opened it will lock back automatically after set time. Push and/or pull to open Metra Electronic Locks are required for this functionality to work properly.

EX: For FW versions releases after beginning of 2017 you should select "EX15", for older versions contact Metra Support for details.

Block RFID media: Select which types of RFID media the device will not read. Useful for dual RFID cards for which you want to read only a specific RFID chip.

Navigation buttons

Update button

 

( Back )